Product Description; Designated Use; Technical Data - ABICOR AIPLAS WELD 250 MT Mode D'emploi

Systeme de torche de soudage
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 Product description

2 Product description

2.1 Designated use

2.2 Use contrary to the designated use

2.3 Technical Data

Welding
Transport and storage
Relative humidity
Tab. 2
Ambient conditions
®
Type ABIPLAS
WELD
Type of use
DC polarity of the electrodes
Voltage rating
Protection type of the machine-side connections IP2X (EN 60 529)
Tab. 3
Product-specific torch data (EN 60 974-7)
Plasma gas (argon, argon/helium, helium)
Shielding gas (inert gas or inert/active gas mixtures)
Tab. 4
Process gases according to DIN EN 439
Type of voltage
Polarity of the tungsten electrode
Polarity of the workpiece
®
Type ABIPLAS
WELD
Operating voltage
Welding current at 100% duty cycle
Tab. 5
Main arc
EN - 4
The welding system ABIPLAS
low- and high-alloy materials. Designated use also includes the observance of
the prescribed operating, maintenance and servicing instructions.
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorised conversions or power increase
modifications are not allowed.
ABIPLAS
®
WELD 250 MT is used for safe welding of
- 10 °C to + 40 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
250 MT
automatic
Usually negative
141 V peak value
0,7 - 5,0 l/min
4,0 - 20,0 l/min
DC direct voltage
cathodic (-)
anodic (+)
250 MT
10 - 40 V
80 - 250 A
®
WELD 250 MT

Publicité

Table des Matières
loading

Table des Matières