Replacing Fuses; Troubleshooting - Dometic PLB40 Notice D'utilisation

Batterie lithium fer phosphate portable
Masquer les pouces Voir aussi pour PLB40:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
PLB40
6.5
Connecting consumer devices
fig. 2, page 3
➤ Open the cap for the desired device:
– USB devices (3)
– 2-pin 12 V DC socket outlet (4)
– 12 V DC socket (5)
➤ Insert your device's plug into the corresponding socket.
✓ The
symbol and the related output symbol light up.
6.6

Replacing fuses

➤ Ensure that the battery pack is not connected to AC/DC or DC/DC charger.
➤ Disconnect all loads.
➤ Press the power button for at least 3 s to switch the battery pack off.
➤ Undo the fuse holder.
➤ Replace the fuse with a 20 A 3 AG glass-slow acting fuse.
7

Troubleshooting

Problem
The battery pack does not
start/function when pressing
the power button.
The display shows the
warning symbol and the
low / high temperature sym-
bol flashes. An error sound is
continuously beeping dur-
ing charging.
EN
Cause
The battery pack has shut
down due to overtempera-
ture (> 65 °C/149 °F).
The battery is defective.
The ambient temperature for
charging the device is too
low / high.
Troubleshooting
Remedy
Connect the AC/DC charger
to the battery pack.
If the battery pack does not
start up, press the reset
button and hold it until for a
few seconds.
Contact a service center.
Stop charging the device.
Turn the device off. Wait until
the ambient temperature
comes to a permitted value
(chapter "Technical data" on
page 16).
13