OPERATING CONDITIONS & REQUIREMENTS
OPERATING PRESSURE MIN-MAX: 1,4-5,0 bar / 20-73 psi
for cold water applications (max. 48 °C (120 °F)) max. operating
pressure is 8,3 bar (120 psi).
this system is configured to perform optimally at an operating
pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a lower or higher
operating pressure the performance may be affected negatively!
check water pressure regularly.
take into account that night time water pressure may be considerably
higher than day time water pressure.
install a pressure reducer ahead of the water softener if necessary.
OPERATING TEMPERATURE MIN-MAX: 2-65 °C / 35-149 °F)
do not install the water softener in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
the water softener cannot be exposed to outdoor elements, such as
direct sunlight or atmospheric precipitation.
ELECTRICAL CONNECTION:
this water softener only works on 24VAC; always use it in
combination with the supplied transformer.
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-current
protection.