Charging NiMH/NiCd batteries
NiMH/NiCd batteries require only one connection to the
charger.
NOTE: As a safety measure, in NiMH/NiCd mode the
charge will stop when the charged mAh counter reaches
the preset mAh value, whether the battery is full or not.
Procedure NiMH/NiCd
 Select memory profile 6 to 10, CHG mode and adjust
the charge settings if necessary.
 Connect the battery to the charger using the
charge lead.
 Press the ENTER/STOP key to start the charge.
 Once the charge is completed, press the ENTER/
STOP key to display the final charge data.
 Press the ENTER/STOP key again to return to the
main screen.
 Disconnect the battery.
14 - English
STORAGE CHARGE LIPO/LIFE
To avoid loss of performance and/or permanent damage,
LiPo and LiFe batteries must be stored charged at 50%
(not full or empty). The charger features a storage charge
function that charges the batteries at 50% of their capacity
(3.85V/cell for LiPo and 3.3V/cell for LiFe).
Procedure:
 Select memory profile 1 to 5, select STR mode
and adjust the charge settings if necessary.
 Connect the battery to the charger using the
charge lead.
 Connect the balancing plug to the correct
balancing port on the charger.
 Press the ENTER/STOP key to start the charge.
 Once the storage charge is completed, press the
ENTER/STOP key to display the final charge data.
 Press the ENTER/STOP key to return to the main
screen.
 Disconnect the battery.
NOTE: Storage mode will only function if the batteries are
charged below 50%. The charger cannot discharge batteries.