4.2
Filling the tank
with fluid
Spout
Fig. 15: Fluid bottle
Fig. 16: Filling the tank with fluid
4.3
Suction of the
excess fluid from
the tank
Fig. 17: Suction of the excess
fluid
Remove the plug from the tank of the Fog
Spray Gun.
First, suck remaining fluid out of the tank, see
chapter 4.3.
Before filling, lay the Fog Spray Gun on its
side.
Insert the long sprout far into the tank (open-
ing "Fill") and fill the tank with fluid.
Control the fluid level in the tank at the Fluid
Level Window. (under the Filling opening, see
fig. 1, part 6). For this purpose, replace the
Fog Spray Gun in an upright position. Fill the
tank to 3/4 full.
NOTE!
Hold the Fluid Level Window to a light source to
easily see the level of the fluid.
If the tank is overfilled or before storing the Fog
Spray Gun, the fluid has to be sucked in the fol-
lowing way:
Squeeze the Fluid bottle.
Insert the long nozzle into the "Empty" tank
and release the pressure on the bottle so that
the excess fluid in the tank is sucked back into
the bottle.
Getting started
EN
27