attempting to charge any severely discharged or heavily sulfated
battery. Once the charger is timed-out, the charger will stop charging
for protecting your battery and the RED LED will be slow FLASH, while
this situation occurs, please check with your battery statues.
• Reverse polarity: The charger has reverse battery protection. If a
reverse battery exists (Red LED ON, while output leads are connected
backwards), simply unplug charger from AC power and properly
remake the connections as described in this manual.
• Short circuit protection: The charger has output short-circuit pro-
tection. If the charger output lead short condition exists (Red LED ON,
while output leads are connected backwards), simply unplug charger
from AC power and properly remake the connections as described
in this manual. The charger employs the firm hardware and smart
program to automatically detect the output connections. Once the
charger detects the output short-circuit or reverse polarity, it will
not deliver any output current.
BATTERY TYPES & CAPACITY
• Suits all Lead Acid Type Batteries. (GEL, SLA, AGM, Calcium).
• 12 Volt Output, Charging current 1500mA.
• Battery Capacity: The following maximum Ah capacities are
to be used as a general guide only: some batteries may be
able to handle a higher Charge Current. Check with the batte-
ry Manufacturer when charging batteries with small capacity.
Charge current
Battery Capacity: charging
Battery Capacity: maintaining
ELECTRICAL PARTS
Delivered with:
• A.C Power Cord:
- 6 feet with VDE Plug
• Output Lead:
- 4 feet with Trailer Connector
• Extension Cord:
- 2 feet with Trailer Connector + Battery Clamp or
- 2 feet with Trailer Connector + Ring Connector
ENVIRONMENTAL CHARACTERISTICS
• Operating Temperature: 0 to 40° C
• Storage Temperature: -10 to 80°C
• Operating Humidity Range: 90% RH Max
FULBAT - www.fulbat.com
STEP 1 - Pre Charge Check & Electrolyte Level Check
• Check the Battery Electrolyte level (Not required on sealed & Main-
• If necessary, remove the vent caps and add distilled water so the
STEP 2 - Connecting the Battery charger to your Battery
• If the Battery is out of the vehicle:
1500mA
4-30Ah
4-120Ah
• If Battery is still in the vehicle, determine if the vehicle is positively
• If Negatively Earthed (Most Common) – FIRST Connect the Red (+)
3
TECHNICAL SPECIFICATIONS
Part number
Type
Approvals
Input voltage range
Input frequency
Output
Size (LxWxH) in mm
Weight
CHARGING INSTRUCTIONS
tenance Free Batteries).
levels are halfway between the upper and lower fill lines.
- Connect the Red lead from the charger to the positive (+) battery
terminal.
- Connect the Black lead from the charger to the negative (-) battery
terminal.
or negatively earthed.
battery charger lead to the positive (+) Battery post and then connect
the Black (-) battery charger lead to the vehicle's chassis and away
from the fuel line.
Fulload 1500
Intelligent
CE
100-240Vac
50/60Hz
1.5A @ 12V
109x71x29
0.45Kg