Mitsubishi Electric Mr.SLIM PKA-M KA Série Manuel D'utilisation page 8

Masquer les pouces Voir aussi pour Mr.SLIM PKA-M KA Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
3. Operation
<Display of unsupported functions>
Title
Not available
Unsupported function
Return:
F1
F2
F3
F4
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
<Vane setting>
Fri
Swing
Off
Off
Vane
Vent.
Louver
F1
F2
F3
F4
Fri
Room
Cool
Set temp.
Auto
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
8
The message at left will appear if
the user selects a function not sup-
ported by the corresponding indoor
unit model.
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 7), and press the [SELECT]
button.
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
5", the vane will be fixed at the se-
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 2" to "Step 5"
and the fan operates at "Mid 1" to
"Low" speed during cooling or dry
operation (depends on the mod-
el).
The icon will go off in an hour, and
the vane setting will automatically
change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY unit
is connected.
Off
Low
High
Off
Low
• The fan on some models of indoor
units may be interlocked with cer-
tain models of ventilation units.
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. I mmediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. I n heat mode, when room temperature is higher than the tem-
perature setting.
<[Manual] To Change the Airflow's Left/Right Direction>
* The louver button cannot be used.
Model PKA-M·KA(L)
• Stop the unit operation, hold the lever of the louver,
and adjust to the desired direction.
* Do not set to the inside direction when the unit is in
the cooling or drying mode because there is a risk
of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
Note: (for wireless remote controller)
R unning the ventilator independently is not available.
N o indication on the remote controller.
High
Press the [RETURN] button to go
back to the Main menu.
F4

Publicité

Table des Matières
loading

Table des Matières