OPERATION
Settings
Note
The following applies to all time programs (Pro1, Pro2,
Pro3):
If the end time is later than 23:59 h, the end time will
automatically be moved to the next day of the week.
The comfort phase is maintained past midnight and
will end on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with
time programs Pro1 and Pro2. During this time period, the
appliance heats to the set comfort temperature. Outside this
specified time period, the appliance operates in setback mode.
This results in a comfort and a setback phase that are repeated
daily (Pro1) or every weekday (Pro2).
Theses phases are factory-set as follows:
- 08:00 h - 22:00 h: Comfort mode
- 22:00 h - 08:00 h: Setback mode
Note
When time program Pro2 is enabled, the appliance
operates exclusively in setback mode during the week-
end.
To adapt time programs  Pro1 and Pro2 according to your
needs, proceed as follows:
In the configuration menu, use " " and " " to call up the
required time program.
Press the "ok" button.
The start time for comfort mode is displayed.
Use " " and " " to set the required start time.
Press the "ok" button.
The end time for comfort mode is displayed.
Use " " and " " to set the required end time.
Press "ok" to save.
Time program Pro3
You can use time program Pro3 to specify up to 14 separate
comfort phases which are repeated weekly.
To configure a comfort phase in time program Pro3:
In the configuration menu, use " " and " " to call up time
program Pro3.
Press the "ok" button.
The display shows "3---".
Press the "ok" button.
A day of the week or a group of days is displayed.
Use " " and " " to select the required day or group of
days.
Press the "ok" button.
The start time for comfort mode is displayed.
Use " " and " " to set the required start time.
Press the "ok" button.
The end time for comfort mode is displayed.
Use " " and " " to set the required end time.
E 500-3000
Press the "ok" button.
Comfort phase "3-01" has been configured.
To configure a further comfort phase, use " " and " " in
time program Pro3 to select display "3---". Proceed as de-
scribe above.
Note
To reset the selected comfort phases, activate param-
eter P4.
Please note that activating parameter P4 resets
all time programs (Pro1, Pro2, Pro3) to the factory
setting.
5.3.3 Parameters
You can call up the following parameters:
Display
Description
P1
Room temperature offset
P2
Time format
P3
Temperature display units
P4
Reset time programs (timer mode).
P5
Reset relative heating time
To change the value of a parameter, use " " and " " to call up
the relevant parameter. Press the "ok" button.
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with " " and " ". Press "ok" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a
difference between displayed actual temperature I1 and the
room temperature you measure yourself. To compensate for
this difference, a room temperature offset of ±3 °C can be set
via parameter P1.
Example: The appliance indicates I1 = 21.0 °C. You have meas-
ured a room temperature of 20.0 °C. There is a difference of
1.0 °C.
To compensate for the difference, select an offset of
P1 = -1.0.
P2: Time format
Parameter P2 is used to specify whether to display the time in
12 hour or 24 hour format.
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature
is displayed in degrees Centigrade [°C] or in degrees Fahren-
heit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
Options
±3 °C | ±5 °F
12 h | 24 h
°C | °F
on | off
on | off