INSTALLATION MANUAL
PCV123D (DGM1D)
Desktop and Handheld Mifare
Refer to the datasheet of the DGM1D controller for more information.
When positioning the jumpers on the controller board?
There are 4 jumpers on the controller which need to be set prior to power the reader. Jumper
must be set according to your confi guration:
- JP1 : The site code setting is enabled
- JP2 : Cardholders programming is enabled
- JP3 : RS232 connection between the DGM1D controller and the PCV123D Terminal unit
Switch off the power on the controller, put the jumpers on and then put the power on.
The new jumper confi guration is set on the controller.
Self-diagnosis
Reader Test: When the controller is powered the LED on the reader lights on amber during 4
seconds and then lights off.
RF Communication
- In case of a communication problem between the Terminal unit and the reader a message
is displayed on the Terminal unit « default connection ».
- Place the back of the Terminal unit against the reader
- The reading area of the Terminal unit should fi t on the reader.
- Remove JP3 jumper
Badges
3 access level badge types can be programmed on the PCV123D:
- Cardholder badges are programmed with the PCV123D Terminal Unit from the Enrollment
badge menu. To activate a badge, the site code of the controller must be programmed
on the badge. The site code is defi ned with a 5-digit + a 6th digit from 0 to 9.
- Cardholder badges can be programmed to grant access to a gate. To program the
cardholder badges for the second reader only, the site code of this reader should be entered
as follow: 5-digit + 6th digit E.
- Master keys are programmed with the PCV123D Terminal Unit from the Enrollment badge
menu. The master keys have access to all sites (reader/door) which have the same 5 fi rst
digit and the 6th digit from 0 to 9. The site code for the master key should be programmed
5-digit + 6th digit F.
Badges 1door+gate
Badges gate
Master keys
cdvi.com
12
cdvigroup.com
terminal
®
Site code
5-digit + 0 to 9
5-digit + E
5-digit + F
controller
# 1 to 10
One
-
all 10 readers
EN
controller
for the gate
Yes
Only
Yes

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pcv123Dgm1d

Table des Matières