Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
The appliance is not
working
The wine chiller is not
cold enough or turns
on/off frequently
The light does not
work
The display shows "EL"
or "EH"

Technical Specifications

Model
Voltage
Power
CE217
220-240V
180W
50Hz
CE218
220-240V
180W
50Hz
8
CE217-CE218_ML_A5_v7_20180403.indb 8
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Temperature incorrectly set
The door is not completely shut
The door gasket is not sealing
properly
The room temperature is warmer
than normal
The door is opened too frequently Reduce number of times door is opened
The light switch is set to "OFF"
Unit may not be plugged in or
switched on
The air temperature sensor has
failed
Bottle
Current
Capacity
1.4A
92
1.4A
155
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Check the temperature setting
Shut door
Check door seal fitted correctly
Reduce room temperature
Set light switch to "ON"
Plug in and switch on chiller
Contact Polar agent or qualified technician
Temp.
Dimensions
Refrigerant
Range
H x W x D mm
R600a 50g
5-22°C
1805 x 595 x 680
R600a 60g
5-22°C
1445 x 595 x 570
Weight
(kg)
73
105