ANGLE MODE: When in angle mode the adapter will hold the highest measured
angle reading on the display until "zero-clear" by pressing and releasing the Power
button (3).
HOW TO SELECT UNIT
1. Press the Power Button (3) more than 2 seconds to Set Mode.
2. When you see the digits start blinking, press the Power Button (3) again to select the
desired measuring unit.
3. When the desired measuring unit is displayed, press the Power Button (3) 2 seconds
to confirm your selection. (or wait for 5 seconds the system will automatically
confirm your selection)
SETTING TORQUE ALARM VALUE
1. Press the Power Button (3) more than 2 seconds to Set Mode.
2. When you see the digits start blinking, press the Up Button (5) and Down Button (4)
discontinuously to adjust the target torque value.
3. If you want to quickly go through to the target torque value, just press it the Up
Button (5) and Down Button (4) continuously.
4. When the target torque value is displayed, press the "Power Button (3)" 2 seconds to
confirm your selection. (or wait for 5 seconds the system will automatically
confirm your selection)
NOTE
1.
When you are reaching 90% of the target torque value, an intermittent buzzer will start to warn you.
2.
When the target torque value is reached, a high-frequent buzzer will warn you not to pull further.
MEMORY FUNCTION
The system will memory the "mode" and "unit" selection which you set even you
change coin cells.
RESET MEMORY FUNCTION
To clean the memory, just press the "Down Button (4)" and "Up Button (5)" together
for 2 seconds.
COUNT FUNCTION
Just press the "Power Button (3)" and "Up Button (5)" together to show how much
times this adapter has been used.
NOTE
The system will record this time automatically when the torque value reaches the target
torque value you set. The counter unit is thousand as shown "K", and the maximum is 999K.
OVERLOAD ALARM/RECORD
1English1
English