Electrical Connections; Exchanging Frontplate; Withdrawing And Inserting The Device - Camille Bauer SINEAX C 402-1 Mode D'emploi

Masquer les pouces Voir aussi pour SINEAX C 402-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Electrical connections SINEAX C 402-1 in housing S17
Potentiometer
for trip point GW 2
Test sockets to GW 2
Potentiometer
for trip point GW 1
Test sockets to GW 1
1
E = Measuring input
A1 = Output contacts for monitoring the trip point GW 1

9. Exchanging frontplate

ON
(
Fig. 4. Left: Removing the transparent cover
Right: Inserting the transparent cover.
Apply gentle pressure to the transparent cover as shown in
the left side of Fig. 4 until pops out on the opposite side.
The label in the cover can be replaced and used for notes.
22
E
1
6
Camille Bauer AG
CH-5610 Wohlen
Switzerland
2
+
1
+
2
1
ON
3
8
4
9
5 10
View
without transparent
cover
GW 1
6
11
4
9
I+
U+
E
A1
Energized:
Deenergized:
ON
(
Front
11
1
6
11
SINEAX
C 402
2
ON
1
13
3
8
13
14
4
9
14
5 10
View
with transparent
cover
GW 2
14
3
8
13
A2
4 – 9
Energized:
3 – 8
4 – 14
Deenergized:
3 – 13
A2 = Output contacts for monitoring the trip point GW 2
H = Power supply
After replacing the label in the transparent cover, the trans-
parent cover can be snapped into the front of the device
again. This is done by inserting it behind the edge at the
bottom and pressing it gently down and to the rear with the
finger until it snaps into place (right side of Fig. 4).

10. Withdrawing and inserting the device

Fig. 5
Space e.g.
for MSK designation
2
Yellow LED
for trip point GW2
Yellow LED
1
for trip point GW1
Green LED for
ON
device standing by
5
10
+
H
(9)
(2)
ON
(
(

Publicité

Table des Matières
loading

Table des Matières