HDA 5500
8 Connecting sensors
One analogue input for a transmitter or sensor is always available as standard. Depending
on the model and type, the HDA 5500 has in addition two extra analogue inputs or one input
for digital signals (frequency / counter function) or a Pt100 input.
8.1 HDA 5500 with one transmitter
Connection example for transmitter with a 4..20 mA sink as input signal,
e. g. HDA 5500-2-0-DC-000 with HDA 4445-A-100-000
(refer to chapter 16 Pin configurations):
HDA 4445-A-...
Connection example for transmitter with a 4..20 mA source as input signal,
e. g. HDA 5500-2-0-DC-000 with EDS 3446-3-0100-000
(refer to chapter 16 Pin configurations):
EDS 3446-3-...
Connection example for transmitter with a 0..10 V as input signal,
e. g. HDA 5500-2-0-DC-000 with HDA 4746-B-100-000
(refer to chapter 16 Pin configurations):
HDA 4746-B-...
1
2
3
4
1
2
3
4
1
2
3
4
User Manual
HDA 5500-...
7
IN1
5
AGND
Input signal sensor 1
HDA 5500-...
7
IN1
5
AGND
Input signal sensor 1:
HDA 5500-...
6
+12 V
IN1
7
5
AGND
Input signal sensor 1:
- 12 -