Copying configuration with FlexProgrammer
Copy the configuration of one sensor to
f
another sensor using FlexProgrammer (see
FlexProgrammer instructions).
8.
Operation
Standard operation with factory settings
BU
Application-specific settings: see chapter "14.3 Factory settings and user settings" on page 12.
9.
Troubleshooting
Fault
LED does not light up
Red LED indicator light
LED flashes red
10. Cleaning, maintenance and repair
Cleaning
Clean, disinfect or sterilize sensor as needed
f
(CIP/SIP).
Maintenance
Regular maintenance is not required.
www.baumer.com
GN
Cause
Sensor not correctly connected
Short circuit
Unsuitable media characteristics
Device error
Operating Instructions
Level measurement
CleverLevel
Point level detection – hygienic/industrial
1
2
BU = blue: SW1 and SW2 active
GN = green: Both switch outputs inactive
Action
Check plug and power supply.
f
Remedy short circuit.
f
Check signal quality with
f
FlexProgrammer.
Dismount and return sensor.
f
Repair
Do not repair the sensor yourself.
Send damaged sensor to Baumer.
f
®
LBFH/I
9 / 33