BATTERY REPLACEMENT
Cut the power supply first.
The battery is replaceable.
Technical specifications battery:
Battery code
Battery
voltage
BAT-HT32-1600LF
3.2V (2.4-3.6) 1.6Ah
The light source of this luminaire is not replaceable; when the light source reaches its end of life,
the whole luminaire shall be replaced.
AUTO TEST FUNCTION
Automatic test
Function test: Weekly
Duration test: Annnually
Green LED
Status (Slow: 1s/1s, Fast: 0.1s/0.1s)
Everything OK (On)
60s function test mode (Slow)
Green / red blinking
Address identification mode
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
A
B
Battery
Battery
Battery
capacity
type
temp.
Li-FePO4
70°C
www.prolumia.com
C
Dimensions
Discharge
(w x h)
current
1 hour: 0.5A
18 x 65mm
3 hour: 0.33A
Manual start of function test
<1mm
Indicator
Test
~1sec
Red LED
Status (Slow: 1s/1s, Fast: 0.1s/0.1s)
Lamp failure (On)
Battery disconnected (Slow)
Battery failure (Fast)
Green & red off
Emergency operation
D
Min. charging
Max. charging
current
current
0.01A
0.13A
9