OPERATING INSTRUCTIONS
1. Turn on the power flushing pump and immediately check all connections,
and the top of the JetFlush Filter cylinder for leaks.
2. After initial circulation for approximately ten minutes, turn both three-port
valves 180° into the BYPASS position.
3. Remove the securing ring from the top of the cylinder and, gripping the
handle firmly, carefully lift out the magnet.
NOTE: the magnet is very powerful and is strongly attracted to steel
surfaces. Take care not to trap fingers and avoid contact with sensitive
equipment.
4. Inspect the magnet for collected deposits and, if necessary, clean as
follows:
5. Grip the cylinder lid and handle with one hand. Whilst wearing disposable
gloves, grip and slide the magnetite sludge down and off the magnet.
NOTE: It is advisable to only remove a proportion of the deposits with each
stroke, starting at the lower end of the magnet, rather than all at the same
time. Clean the end of the magnet.
6. Collect the sludge in a suitable container for later disposal.
7. Re-assemble the JetFlush Filter ensuring that the magnet locates within the
circular recess at the base of the cylinder, and turn both three-port valves
back into the CIRCULATE position.
8. Repeat the inspection and cleaning procedure as required during the
flushing process.
JetFlush Filter V1-07-16