EN
CONNECTING THE FILTER (CONTINUED)
1. Place the JetFlush Filter adjacent to the power flushing pump on a suitable
drip tray.
2. Select the required direction of flow and position the pump flow reverser
lever in that direction.
3. Install the filter on the flow from the flushing pump using the short
(1.5 metre) hose supplied. Connect the flow to the bottom connection on
the filter.
4. Using the power flushing pump standard flow and return hoses connect
both the pump and the top connection on the JetFlush Filter to the heating
system.
5. Both JetFlush Rapid three-port valves should be in the CIRCULATE position.
6
CIRCULATE
BYPASS
mode
mode
JetFlush Filter V1-07-16