GCE LORCH LOMAT PROPALINE Notice D'utilisation page 6

Masquer les pouces Voir aussi pour LORCH LOMAT PROPALINE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
2.3. FUEL GAS SETTING
Slowly open the gas bottle valve. Adjust the working pressure at the propane
controller (marked on the burner). Move the main shutoff and regulating valve (2)
on the Lomat to "open" to release the gas supply.
Ignition of Lomat/Lomat Piezo
The Lomat/Lomat-Piezo can only be ignited when:
EN
the burner is locked in the handle (Fig. 2)
the regulating valve is open (2, Fig. 3)
the working pressure is properly adjusted
With shrinking burner:
Open tha air slide on the shrinkage burner (Fig. 4)
2.4. MANUAL IGNITION WITHOUT IGNITION LEVER
Open the main shutoff and regulating valve. Ignite using the gas igniter at the
burner head.
2.5. MANUAL IGNITION WITH IGNITION LEVER
Open the main shutoff and regulating valve (2). Release the gas by pressing the
ignition lever (3). Ignite using the gas igniter at the burner head.
2.6. AUTOMATIC IGNITION
Release the gas supply by pressing the ignition lever (3), and the burner is simul-
taneously ignited by the piezo ignition spark.
2.7. ADJUSTING WORK FLAME
The amount of gas is increased (towards "open") or reduced (towards "shut")
using the regulation system (2) (Fig. 3).
Continuous operation
2.8. CONTINUOUS OPERATION WITHOUT LOCKING BUTTON
Hold down the ignition lever (3).
2.9. CONTINUOUS OPERATION WITH LOCKING BUTTON
The unit is set to continuous operation by pressing the locking button (5).
To release the locking device activate the ignition lever (3). Burners with a fl ame
length > 150 mm should not be set down when set to continuous operation.
2.10. HEATING TORCH RETENTION FLAME SETTING
(Torch without piezo ignition) When the heating torch is set down, the fl ame
should be automatically reset to "retention fl ame". The fl ame is adjusted using
the retention fl ame adjusting screw (6). The fl ame is shut off using the main
shutoff and regulating valve (2).
2.11. USING SOLDERING AND SHRINKING BURNERS
Air slide closed - shrinking fl ame open - soldering fl ame (see Fig. 4).
2.12. CHANGING BURNERS
The burner is released by pressing the unlocking button (7), and the gas supply
is shut off sumultaneuously.
2.13. INTERRUPTING WORK
- Close the regulation valve (2) by moving towards "shut" (Fig. 3). Ignition lever in
"off " position. The burner can be set down on its fold-out stand (8).
6/52

Publicité

Table des Matières
loading

Table des Matières