Télécharger Imprimer la page

The Display Screen; Operation - Trotec BM20 Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
sured results it must however be taken into account that increased
levels of soluble salts present in the material can falsify the results
obtained.
The higher the level of salts, the higher the measured values. Exact
statements on the moisture content of materials containing mine-
rals are only possible by applying the kiln drying method or the CM
method.

03. The display screen

u Display of battery status
v Display of measured values
w Dampness scale for wood moisture measurements
x Dampness scale for building moisture measurements
B - 4

04. Operation

Switching on and off
Remove the protective cover y from the lower face of the instru-
ment U . This procedure automatically switches the instrument on.
To switch off replace the protective cover on the lower face of the
instrument. By means of this procedure the instrument automati-
cally switches itself off.
Automatic switch off: If an instrument that is switched on is not
used for any measurement within a period of approx. 15 minutes,
the instrument automatically switches itself off to preserve battery
life. In order to bring the instrument back into the switched-on
state, push briefly on the activation pin W that is fitted between
the electrode pins X .
Operating manual – Moisture meter
G

Publicité

loading