Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 111
Operating instructions pressure measuring devices SATA adam 2, SATA adam 2 U
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery replacement in explosive areas!
• Installation of a battery other than CR 2032, RENATA (SATA Art. No.
160739)!
7.

Use [2]

• Please disconnect spray gun from the air supply prior to the installation of
the SATA adam 2 to the spray gun.
• Please ensure that all screws are firmly tightened.
Steps 1. - 4. only apply to the SATA adam 2 (mini)
Loosen and remove the locking screw [2-1].
101.
102.
Remove air micrometer (air flow control knob) [2-2].
103.
Insert SATA adam 2 [2-3] in the spray gun.
104.
Tighten locking screw firmly [2-4].
Danger!
• Check if locking screw has been firmly tightened! SATA adam 2 (mini)
could otherwise shoot out from the spray gun in an uncontrolled way!
7.1. Disassembly and Assembly of the Display [3]
Disassembly:
• Place the regulation wing [3-1] in the horizontal centre position.*
• Press down the locking clip [3-2] and slide display [3-3] upwards out of
the groove.
Assembly:
• Place the regulation wing [3-4] in the horizontal centre position.*
• Place display [3-5] correctly in the groove and slide in until it snaps
home.
* only for SATA adam 2 (mini)
Danger! Risk of explosion!
Danger! Notice!
US
305

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Adam 2 miniAdam 2 displayAdam 2 uAdam 2 black

Table des Matières