13
Control panel
32
C
58
56
VRD
VRD
55
36
54
B
27
Abb. 8:
T-series AC/DC ControlPro control panel
A Mode
The mode button
20
selects the mode.
LED Electrode
21
lights up if you select the electrode mode.
LED Pulse
22
lights up if you select the pulse mode.
LED Spots
23
lights up if you select the spots mode.
LED Tiptronic
24
lights up if you select the tiptronic mode.
LED 4-stroke
25
lights up if you select the 4-stroke mode.
LED 2-stroke
26
lights up if you select the 2-stroke mode.
B Current mode
The current mode button
27
selects the welding current type DC, AC, with or
without HF ignition and MACS.
LED Alternating Current (AC)
28
1
lights up if you select the AC welding process.
LED Direct current +
29
1
lights up if you select operating mode DC+ (posi-
tive polarity on the connection bush 3)
Only for AC/DC
1)
- 40 -
37 38 39 40 41 42 43
31
30
29
28
1
1
1
909.1709.9-05
45
34 46 47
48 49 50 51
1
26
25
24
23
22
LED DC -
30
1
lights up if you select operating mode DC - (nega-
tive polarity on the connecting bush 3)
LED HF
31
lights up if you select the function HF, for touch-
less ignition.
C Welding parameters
The selection button on the left
32
allows you to select the individual welding param-
eters.
The selection button on the right
33
allows you to select the individual welding param-
eters.
The knob
34
allows you to adjust the welding parameters.
7-segment display
35
displays the welding parameters and tiptronic job
no.
7-segment display
36
displays parameter codes and the welding pa-
rameter ampere or seconds.
LED Remote control
37
lights up with an activated remote control
LED Gas pre-flow time
38
lights up for selected parameters. The gas pre-
flow time can be changed with knob (34).
Control panel
33
21
20
04.19
57
59
52
35
53
A