• Shorten stepped hose adapters such that the connection opening coincide with the hose diameter. This helps to
avoid pressure loss.
• Push the union nuts over the stepped hose adapters, push or turn on the stepped hose adapter, and secure with the
hose clips.
• Insert the flat sealing ring or the O ring into the union nut for the black hose adapter and screw onto the pressure
filter inlet.
Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.

Protective measures:

• Only operate the unit with the protection hood fitted.
• Ensure that the unit is installed water-tight with a safety distance from the water of a minimum of 6.6 ft
(2 m).
Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC).
B
• Place the pressure filter in a flood protected position at a distance from the pond edge of at least 6.6 ft (2 m) on firm
and level ground. As an alternative, the filter can also be partly buried up to approx. 2 in (5 cm) below the closing
clamps.
• The height difference between the filter lid and the free outlet point may be max. 6.6 ft (2 m).
• Ensure unrestricted access to the cover to be able to carry out work on the unit.
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention! Never operate the unit with a water pressure of more than 2.9 psi (0.2 bar)!
C

Important:

• Switch the pump on first, then the UVC clarifying unit.
• Do not operate the unit without water flowing through.
• The unit switches on automatically when power connection is established.
Switching on: Connect power plug to the socket.
• The control lamp is lit.
Note:
• After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
• The full effect on bacteria is only reached as from a water temperature of 50 °F (+ 10 °C).
• In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off: Disconnect the power plug.