7 .
Pull the supply wires out of junction box (not included)
and through the large hole in the center of the
attachment plate.
8.
Secure attachment plate to the wall using four bolts
(not included).
9.
Pull the supply wires into the center hole of the
decorative wall plate and into the fixture assembly
(passing through the silicone rubber wire grommet)
from step 6.
10. Hang the decorative wall plate onto the attachment
plate and tighten the screw located at the bottom of
the decorative wall plate to 15 in-lbs.
11. Inside the fixture, connect supply wires to
appropriate fixture leads:
a. Supply side ground wire to green fixture lead.
b. Supply side neutral wire to white fixture lead.
c. Supply side line voltage wire to black fixture lead.
12. Close the cover and tighten the three screws to
insure the fixture will maintain its water tight seal.
Threaded Rod
Mounting Arm
(Angled edge torward fixture)
Decorative Wall
Plate
Attachment Plate
(Hardware by Others
Wall Gasket
Figure 2.
Tools Required
#2 Phillips screw driver, Drill and 7/16" drill bit, Ratchet
and 9/16" socket.
Mast Arm Adapter Mount (Figure 3.)
1.
Loosen (3) screws located in the access door of the
fixture and open the door.
2.
Pull all supply wires through the mast arm/mast
arm adapter and into the center grommet located
between the mounting bolts at the back of the
fixture.
Access Door
Mounting Hardware Detail
(Washer/Lockwashers and Nuts)
Installation Instructions – Galleon /Galleonaire
3.
Install the 1st mounting bolt (1/2"-13 x 1 1/4") and
lockwasher through the top side hole at the back of
the fixture and into the mast arm adapter.
4.
Install the 2nd mounting bolt (1/2"-13 x 1 1/4") and
lockwasher through the bottom side hole at the back
of the fixture and into the mast arm adapter.
5.
Slip the assembly over the mast arm (making sure
not to pinch any supply leads). Make sure the mast
arm is fully seated into the mast arm adapter as it
should bottom out against the adapter.
6.
Secure the mast arm adapter to the mast arm with
the (4) 3/8-16 x 3/8" set screws. Tighten set screws
to 12.5 ~ 13 ft-lbs.
7.
Drill a 7/16" hole through the mast arm and install
the 3/8" carriage bolt and nut. Use care when
drilling this hole so as not to damage any wires
within the mast arm.
8.
Inside the fixture, connect supply wires to
appropriate fixture leads:
a. Supply side ground wire to green fixture lead.
b. Supply side neutral wire to white fixture lead.
c. Supply side line voltage wire to black fixture lead.
9.
Close the cover and tighten the three screws to
insure the fixture will maintain it's water tight seal.
1/2"-13 x 1-1/4"
Mounting Bolt and
Lockwashers
Figure 3.
COOPER LIGHTING SOLUTIONS IB500021EN
Mast Arm
Adapter
3/8"-16
Carriage
Bolt
Set Screws
Insert Over
Mast Arm
Installation instructions
3