AUTOMATIC
OPERATION
SILENT OPERATION
NIGHT-TIME
OPERATION
OPERATION
AT MAXIMUM
VENTILATION SPEED
06 AUTOMATIC OPERATION / SILENT OPERATION / NIGHT-TIME OPERATION
Key
Operation
Press and hold the AUTO key. The function being
activated is indicated by the relevant symbol
appearing on the display.
Ventilation speed adjustment is carried out automatically between the
minimum and maximum values, according to the distance of the actual room
temperature from the set point, according to a PI-type algorithm.
Key
Operation
Press and hold the Silent key. The function being
activated is indicated by the relevant symbol
appearing on the display.
Ventilation speed is limited to a contained maximum value.
Key
Operation
Press and hold the Night-time operation key. The
function being activated is indicated by the relevant
symbol appearing on the display.
By selecting this mode, ventilation speed is limited to a very contained level
and the set temperature is adjusted automatically, as follows:
-
decreases by 1°C after one hour and by another degree after two hours in
heating mode;
-
increases by 1°C after one hour and by another degree after two hours in
cooling mode;
Key
Operation
Press and hold the Max Operation key. The function
being activated is indicated by the relevant symbol
appearing on the display.
In this operation mode, the maximum possible power level is activated
whether heating or cooling.
Once the desired room temperature is reached, we recommend selecting one
of the other 3 operation modes for increased comfort and sound levels.
Display
Display
Display
Display