Télécharger Imprimer la page

Outdoor Unit Installation - Qlima S95 Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62

OUTDOOR UNIT INSTALLATION

1.
Fit the drainage outlet and drainage hose (only for models with a
heat pump).
Condensation will drip off the outdoor unit when the indoor unit
is operating in Heating mode. Fit a drainage outlet and a drainage
hose in order to drain the water effectively. Fit the drainage outlet
and rubber washer to the base plate of the outdoor unit (see fig.).
2.
Installing and fitting the outdoor unit
Bolt the unit to a level and solid base.
Ensure that the unit is mounted securely in order to prevent problems caused by strong wind and
vibrations.
3.
Connecting the outdoor unit pipes
Remove the covers of the two-way and three-way valve.
Close the pipes separately with the appropriate tightening moment.
4.
Outdoor unit cable connection (see previous page)
Air purification
The humid air that remains after cooling may damage the compressor. Air and moisture can be removed
with the aid of a vacuum pump after the indoor and outdoor units have been connected – see below.
Note: Do not purge air contaminated with refrigerant directly to the outside.
4
92
Vacuum pump
Three-way valve diagram

Publicité

loading

Ce manuel est également adapté pour:

S125S185S245