Télécharger Imprimer la page

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
A

SPECIFICATIONS

To be used as indication, subject to modifications.
Model
Cooling capacity *
Warming capacity
Dehumidification capacity **
Power consumption cooling
Power consumption warming
Mains
Current
Maximum airflow
Room size
Dimensions indoor unit (HxWxD)
Dimensions outdoor unit (HxWxD)
Weight indoor unit
Weight outdoor unit
Refrigerant
Noise level indoorunit (max)
Noise level indoorunit (nom)
*
cooling capacities are measured at 27°C, 60% RH
** moisture removal at 32°C, 80% RH
4
84
S95
kW (BTU/h)
2.7 (9000)
kW (BTU/h)
2.8 (9500)
Ltr/day
24
kW
0.78
kW
0.76
Volt/Hz/Ph
220-240/50/1
A
3.6
3
m
/h
430
3
m
75
mm
250x770x179
mm
540x700x255
kg
10
kg
36
gr
R407C/700
dB
36
dB
50
S125
S185
3.5 (12000)
5.3 (18000)
3.75 (12800)
5.7 (19000)
28
36
1.1
1.9
1.4
1.9
220-240/50/1
220-240/50/1
5.1
8.7
550
730
100
150
250x770x179
313x1036x204
540x760x255
660x890x307
12
13
40
53
R407C/1450
R407C/1800
40
43
52
53
S245
7.0 (24000)
7.0 (24000)
48
2.6
2.6
220-240/50/1
12.8
1000
200
313x1036x204
660x890x307
15
58
R407C/2540
47
57

Publicité

loading

Ce manuel est également adapté pour:

S125S185S245