1. Remove the vent filter shipping bracket screws and bracket.
A. Vent filter shipping bracket
B. Screws
2. Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise, and the blower will start. Position the top trim over the
retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
EXTERIOR-MOUNTED VENT MOTOR
IMPORTANT: Exterior blower Model Number KPEU722M
[1200 cfm (34.0 m
3
/3)] cannot be used with this retractable
downdraft vent system.
NOTE: Exterior-mounted vent motor installations require exterior
blower system, Model Number KPEC992M [900 cfm (25.5 m
available from your dealer or authorized parts supplier.

Venting Methods

Determine which venting method is best for your application. Vent
system can terminate through either the wall or roof.
Island location - front vent
16

Check Operation

A
B
INSTALLATION INSTRUCTIONS
For information on ordering, see the "Assistance or Service"
section.
E
3. Slide the control slider on the side of vent to check the
operation and speed of the blower.
4. If the blower does not operate:
Check that filter or filters are pressed in as far as they will
go.
Check that the circuit breaker has not tripped or a
household fuse blown.
Check downdraft vent fuse located under power board.
5. Connect vent system to blower. Vent system must end with a
wall or roof cap. Use clamps to seal all joints.
6. Install cooktop according to manufacturer's instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by ³⁄₈" (9.5 mm). See "Countertop Cutout
Dimensions" in the "Location Requirements" section.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the "Vent System Use" section.