Electrical Installation
•
Lift off domed cover (A) after
removing the 4 screws (B).
•
Take power supply board (C) out of
the domed cover (A) after removing
the screw (D).
•
Guide cables for power supply (E)
and potential-free contact (F) through
screwed cable fittings.
•
Terminals - Check type plate (G) for
permissible mains voltage and ensure
conformity.
In the case of 24 Vdc operation, do not
connect +24 Vdc to frame because the
internal housing potential of the device is
negative.
•
Connect potential-free contact (F) to
terminals 0.6 - 0.7 (fail safe) or 0.7
- 0.8 (open during malfunction).
•
Pull cable (E + F) tight and screw
down cable fittings.
•
Screw power supply board (G) with
screw (D) into domed cover (A).
•
Plug ribbon cable (H) into control
PCB (K).
•
If the individual wires have not been
screwed into the plug, they should be
attached as follows:
1.0 = brown
1.1 = blue
2.0 = black
•
Put on top of cover (A)
and tighten the 4 screws
(B).
The power supply board (C) is
in a reverse position (upside
down) in the domed cover (A).
During no-load operation, a
voltage of up to 36 Vdc may
be measured at terminals 1.0
and 1.1 (plug ribbon cable (H)).
Please ensure that the
installation is carried out
according to the valid
regulations.
14
K
H
K
H
Quincy Compressor-Q MAT 06 Condensate Drain
B
A
C
H
K
G
F
C
E
F
G
C
E
E
F
D
V
-
AC
VOLTAGES
0.8
NORMALLY OPEN
0.7
COMMON
0.6
NORMALLY CLOSED
0.2
PE E
/G
ARTH
ROUND
0.1
N
N
EUTRAL
0.0
L
P
HASE
24 V
-
DC
VOLTAGES
0.8
NORMALLY OPEN
0.7
COMMON
0.6
NORMALLY CLOSED
+24V +24 V
(0V)
DC
+24V 0V (+24 V