Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Calibration Function
Default parameters:
Language = UK
Set Point value= 7,4 pH; 750 mV (Rx)
Dosing Method = Acid; Low (Rx)
Time OFA = OFF
Calibration = Full
Flow Input= OFF
Type dosing= PROP
0000137934
prog
enter
ENT
CAL
cal
prog
ESC
esc
set
MODE
Display
Level 7,2 ph
Ofa alarm 7,2 ph
Ofa stop 7,2 ph
Flow 7,2 ph
Parameter error
Error 7 ph Error 4 ph
Error 465 mv
To restore Default parameters run Following steps:
Power off Pool Basic unit
Keeping Press UP and DOWN Key switch on the Power.
The unit will flash Init.default no
Press up Init.default Yes
Enter Key to restore Default parameters.
rev. 1.0
Relay
Alarm Relay Close
- Push Enter Key to open
Alarm Relay
- Restore Product tank
Alarm Relay open
- Push Enter Key to reset
Alarm Relay Close
- Push Enter Key to reset
Alarm Relay open
- Restore Flow Rate
Alarm Relay Open
- Press Enter Key to replace
Default parameter
- Destroy Unit
Alarm Relay open
- Restore Probe or Buffer
solution and repeat calibration
function
Actions to do
6