FITTING AND CONNECTING THE APPLIANCE TO A GAS CYLINDER
The appliance may only be fitted to standard LPG refillable cylinders.
- Place the mounting bracket on to the collar of the gas cylinder.
- Tighten the mounting screw so that so that it engages with the collar of the gas cylinder
and so that the appliance and the mounting bracket are securely fixed on the gas cylinder.
- If the appliance cannot be mounted in a stable way, it may not be turned on.
- Check the condition of the hose and the pressure regulator each time you use the appliance.
Do not use a hose or regulator that show any sign of damage or deterioration.
- Connect the pressure regulator to the gas cylinder.
- Connect the gas hose to the pressure regulator and to the appliance connector. Make sure
that the hose is routed in such a way so that it is not twisted or subject to strain and so
that it can not come into contact with any parts of the appliance that may become hot.
- Open the gas cylinder valve. Check that all connections are air-tight. If necessary use a leak
detector spray or a soapy solution. If necessary, tighten the connections. Do not use the
appliance if you suspect that the system may be leaky.
USING THE APPLIANCE
Proceed as follows to light the appliance and adjust the flame:
- Place the appliance and gas cylinder assembly outdoors on a level and stable surface, well
away from any inflammable materials.
- Open the gas cylinder valve by turning the knob anti-clockwise.
- Push and hold the appliance's knob and turn it to the highest setting.
- Models 035985 & 035987: Push the Piezo ignition button.
- Models 035984 & 035986: Light the appliance by applying a gas lighter to the section of
the ceramic grille furthest away from the valve.
- Hold the appliance's knob depressed for approximately 20 seconds. If the flow of gas stops,
repeat the steps above.
- Once the flame is established the flame can be adjusted as required by turning the valve.
- To switch off the appliance extinguish the flame by closing the cylinder valve and subsequently
close the appliance valve.
MAINTENANCE AND CLEANING
CHANGING THE GAS CYLINDER
- The gas cylinder may only be changed outdoors, well away from sources of ignition and
other persons.
- Close the gas cylinder valve and the gas appliance valve.
- If the appliance has been in operation allow it to cool down completely.
- Unscrew and remove the gas regulator.
- Unscrew the mounting screw and remove the mounting bracket and the appliance from
the gas cylinder's collar.
- Proceed as described in the 'Fitting and connecting the appliance to a gas cylinder'
section.