Measuring Arrangements - WIKA PGT01 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Installation and commissioning / 5. Measuring arrangements
Installation using
a spanner
If the pressure transmitter is positioned lower than the pressure test
connection, the tailpipe has to be rinsed thoroughly prior to fitting the gauge
to remove all foreign substances.
Once the pressure and electrical connections have been made, the trans-
mitter is ready for immediate use.
Before dismounting the pressure instrument the measuring element has to
be depressurized. Eventually the stress of the pipe has to be relieved.
Residual pressure medium remaining within the pressure
element may cause harm to men, facilities and environment.
Therefore sufficient precautionary measures have to be
taken.
Pressure connector
In accordance with the general technical regulations for pressure gauges
(e.g. EN 837-2 „Selection and installation recommendations for pressure
gauges").

5. Measuring arrangements

Proven measuring arrangements for various types of media.
Liquid media
Liquid
Contents of
tailpipe
Typically
Conden-
sate
Pressure
instrument
higher than
tapping point
Pressure in-
strument lower
than tapping
point
WIKA operating instructions intelliGAUGE / switchGAUGE
Liquid
Vapour
with
only
vapour
Boiling
Liquefied
liquid
gas
Gaseous media
Gas only
Wet gas
Dry air
Moist air,
Flue gas
GB
Liquid
gas con-
densate
Steam
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pgt21Pgs25Pgt02Pgs05Pgt10Pgs06

Table des Matières