Condenser Cleaning - Nordcap O12 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
5.3. Cleaning
To ensure proper hygiene and maintenance, perform regular cleaning as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Clean the surfaces using a dampened cloth with a mild detergent water solution; then rinse with a dampened cloth with clean water
and finally wipe with a dry cloth;
Do not use cleaning products containing acids or chlorine (such as bleach), or abrasive materials (such as pads) or pressurized water
(such as hoses).

5.4. Condenser Cleaning

To ensure long life and correct operation of the refrigeration system, clean the condenser regularly as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Unscrew and open the front and right side air vents grid; be careful with cable holder, do not stretch the cables;
Carefully vacuum (preferably) or brush the condenser coils;
Finally, screw back the air vents grids.
5.5. Extended Period of Inactivity
Where there is a foreseeable extended period of inactivity, remove all foodstuff from the appliance and clean it as well as the condenser as
described. In the end, switch it off from the mains and leave the door open to prevent bad odour.
5.6. Power cord replacement
IF DETERIORATED, THE POWER CORD MUST BE IMMEDIATELY REPLACED BY AN ORIGINAL ONE PROVIDED BY THE
MANUFACTURER OR BY AFTER-SALES SERVICE. THE REPLACEMENT MUST BE PERFORMED BY QUALIFIED PERSONNEL.
5.7. Noise emissions
The A-weighted noise level (dB) of our equipment, at work, does not exceed 70 dB (A).
5.8. Troubleshooting
If you notice any malfunction, refer to the checklist below to identify the problem and its possible solutions. If the problem still persists, please
contact the after-sales service.
Equipment does not run and the display does not work
Equipment does not run but the display works
Equipment is not cold enough
Equipment is too cold
Equipment runs continuously
Equipment starts and stops frequently
MNS00057.00
PRT
Instruction Manual
Symptom
Make sure the plug is inserted into the socket
Check for a blown fuse or tripped circuit breaker
Test the power outlet for current
Inspect the electrical cord for damage
Remove any extension cord
Check the temperature setting
Assure that there is enough air flow inside the equipment
Clean the condenser coils
Check the temperature setting
Assure that there is enough air flow inside the equipment
Check for airflow restrictions in vents
Clean the condenser coils
Clean the door seals
Check the temperature setting
Clean the condenser coils
Clean the door seals
Clean the condenser coils
N.º MNS00057.00
Check
5/23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

O14

Table des Matières