Troubleshooting
Error code
E1
E2 / E3
EE
Cause
Fault with
temperature sensor on evaporator
Error on air humidity
and temperature sensor
Leak in the cooling circuit
Solution
The device is working again, but de-icing
is carried out approx. every 20 minutes
and takes up to 8 minutes.
If the device is currently not carrying out
de-icing, briefly disconnect the device
from the mains network. If the error
persists after restarting, contact customer
service.
The device is working again and dehumi-
difies on a continuous basis, irrespective
of a humidity.
Humidity and temperature sensor must
be replaced, if required. Contact customer
service.
Briefly disconnect the device from the
mains network.
If the error persists after restarting,
contact customer service.
ENGLISH
19