Battery monitor

The battery monitor (21) is integrated in the VB 06-1 junction box and protects
the supply battery (Battery 2) from damaging exhaustive discharge by low-
rating user.
Function
Permanent user with low current consumption, such as solenoid valves on
boilers, can cause the supply battery to discharge very slowly. Over a
prolonged period, this may lead to total discharge of the battery, making it
unusable. The battery monitor automatically monitors the battery voltage. It
actuates the ON/OFF outputs as a function of the main switch position and the
battery voltage.
Switching thresholds
Main switch
Battery voltage
position
ON
11.0V or less
ON
12.5V or more
OFF
12.4V or less
OFF
12.5V or more
30
Lerchenfeldstr. 9 87600 Kaufbeuren Phone: +49 (0)8341 9764-0 Fax: +49 (0)8341 67806
Outputs
Delay
Switching off
3 minutes
Switching on
none
Switching off
3 minutes
Switching on
none