7 Coding
After the first connection to the mains each receiver SHR-7 L3 could be programmed (taught) with 2 individual
address codes with transmission-key
for each relay-output.
For programming the code and transmitter-keys, perform exactly as follows:
• Set the transmitter (Series SH-7 C) to be used to your individual radio-code.
• Briefly press one of 3 "learn" buttons (e.g. S1 for Relais K1) .
Flashing LED indicates active in learning mode.
• On the transmitter press the button selected for your application (e.g. Key 1 or Key 2+3 together) until the LED
flash rate increases.
• The button and radio-code is stored in the receiver. LED continues flashing until the storing procedure is
complete.
• Check for error free operation of the receiver by pressing the transmitter button(s) again when LED is
extinguished. If the address is learned correctly, the clicking operation of the relay will be audible.
• Repeat the procedure for the next relays.
Up to 6 codes could be learned by this way (3x2 per relay). Therefore an older code could be deleted by learning
the new one twice.
The learn mode is completed automatically within approx. 60 sec. In case of error the teach mode may be
interrupted by pressing 2 of the buttons simultaneously.
Pressing learn mode buttons 1 and 3 for a minimum of 3 sec. will delete all stored data.
In normal operation the LED illuminates if an understandable radio signal is received by the SHR-7 L3, even if it is
not a previously learned signal (HF-Busy).
In case the programmed transmitter-code or transmitter itself should be changed, it is a requirement that
the receiver also be programmed with the new code.
Operation of the receiver with an unlimited no. off transmitters is possible by coding the internal tri-dip-switches off
all transmitters to the same code.
Technical Details
: 230V AC / 6A oder 30V DC / 5A
Radio-Frequency
Output
Switched Rating
Antenna
Operating Voltage
Operating Current
Ambient temperature
Dimensions
00373.93 / SHR-7 L3
433,92 MHz
3 isolated change-over-contacts
230V AC / 6A or 30V DC / 5A
λ/4-Wire
230V / 50 Hz
approx. 15 mA (< 4 W)
o
-20
C to +65
approx. 130 mm x 85 mm x 37 mm
- 8 -
o
C