Installation
8.1.1
Note on transport
• Pay attention to the orientation of the up arrows on the carton. Do not install
the unit if it has been upside down for any period of time (fig. 4 A,page 4).
• Always have someone help you carry the roof air conditioner.
• Always lift the roof air conditioner to move it and never drag it over the roof
(fig. 4 B,page 4).
• Do not use the ventilation slots to lift it (fig. 4 C,page 4).
8.1.2
Note on installation location
• Before installing the roof air conditioner, check whether any vehicle compo-
nents could be damaged by the installation of the roof air conditioner (such
as lamps, cupboards, doors).
• Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of
the air conditioner when the vehicle is in motion. The manufacturer of the roof
air conditioner assumes no liability whatsoever.
• The vehicle manufacturer may have already provided points where the open-
ing for the installation of the roof air conditioner can be made without any risk
of weakening the construction or cutting power cables.
• Select a flat and sufficiently level area at the centre of the vehicle roof
between two longitudinal sections for installation.
• The roof inclination of the installation surface may not exceed 10°.
• Make sure no combustible objects are stored or installed near the air outlet.
A distance of at least 50 cm should be kept.
• Make sure that there are no objects within the vehicle which could obstruct
the attachment of the air outlet unit or the cooled air from flowing through the
swivelling air distribution nozzles.
• For safety reasons, note the location of existing wiring harnesses, wires and
other components within the installation area, in particular those which are
not visible, when installing the roof air conditioner (when drilling or screwing
etc.).
8.1.3
Note on electrical system
• Only a qualified electrician should connect the roof air conditioner to the
electrical power.
• Check that the voltage specification on the type plate is the same as that of
the power supply.
• Do not lay cables which are loose or bent next to electrically conductive
material (metal).
14
FreshJet3000
EN