Gallagher 3E1803 110V Notice D'installation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gallagher 3E1803 110V Energizer User Manual
b)
Ground Clamp
(352HD)
Follow grounding instruc ons carefully.
The most eff ec ve place for a ground system is in con nuously damp soil, see
illustra on a. For dry areas with poor condi ons, see illustra on b.
Install the ground system at least 33 from any power supply ground rod,
underground telephone or power cable. Drive one 6 ground rod into the ground,
un l only 2" remain above the ground.
To a ach the ground cable:
1.
Using double insulated cable, remove 2" of plas c coa ng from one end of the
cable wire.
2.
Connect the ground wire to the energizer.
a.
Bend the end of the wire to form a loop.
b.
Unscrew the green (GROUND) terminal on the energizer and insert the
loop of wire between the washers.
c.
Screw the terminal closed, ensuring the wire is fi rmly clamped.
3.
Lay out the cable down walls and out to the ground rod.
4.
A ach the cable to the ground rod by removing 4" of insula on from the cable
at the ground rod, then clamp the exposed wire to the stake using a ground
clamp.
5.
Tighten the clamp.
Note:
Poor grounding can cause interference on telephone lines, radios and
televisions. This can be recognized by a clicking sound on telephones.
A ground wire return system
(for areas with poor grounding systems)
HobbyMaster
M50
GREEN
Ground Rod(351)
The livestock must touch both a hot wire and
the ground wire to feel an eff ec ve shock
RED
The top and bo om wires are electrifi ed
and the middle is the ground wire.
5-Step Installa on Guide
Hot
Ground
Hot
9

Publicité

Table des Matières
loading

Table des Matières