6. MAINTEINANCE

6.1 TeCHNICAL ADVICe

-
If during operation you experience
an irregularity that is not dealt with
in section "maintenance of the
vacuum machine" please switch off
the machine and get it inspected by
a qualified person.
-
No maintenance or repair work
should be carried out on the machi-
ne unless it is disconnected from
the mains first.
-
We recommend every 4-5 years a
general check of the electric motor,
the bearings, cables including a
replacement set of brushes if
necessary and a new filter should
be installed.
6.2 Ordinary maintenance
All these operations are to be carried
out on the machine disconnected
from the mains first and when the
cleaner is chilled from the surrounding
temperature.
This maintenance is made to keep the
cleaner working properly and to
extend the lifetime of the cleaner.
Disconnect the mains first also to
clean the cleaner outside and pay
attention that the dust canister is
properly fixed on the cleaner's body .
eMPTYING Of WAST
CONTAINer
1. Unclip the waste unit from the
machine
38
Impianti aspirapolvere centralizzati
Zentralstaubsauganlagen
Central vacuum systems
Système d'aspiration centralisée
2. Remove the cyclonic separator and
bag support frame
3. Empty the waste container or replace
the plastic bag.
Cod. ER627 x Mod.ZSA25/2/DD
Cod. ER628 x Mod.ZSA45/2-3/DD
4. Reassemble the cyclonic separator
and the bag support into the waste
container ensuring all parts are
clean and not damaged.