BACK BAR COOLER
USER & INSTALLATION GUIDE
SPECIAL MAINTENANCE
The instructions given in the following paragraph are for SKILLED PERSON.
Periodic Operations
• Periodically clean the condenser using suitable tools (vacuum cleaner or soft brush).
• Check that the electrical connections are not loosens.
• Check that the thermostat and the sensor are in proper working order.
• Periodically cleaning the condenser can extend the life of the appliance.
• Failure to keep the condenser clean will reduce the refrigeration performance of the cabinet.
• Recommend that an agent or qualified technician clean the condenser.
TROUBLESHOOTING
If your appliance develops a fault, please check the following table :
Fault
The appliance is not working
The appliance turns on, but
the temperature is too high/
low
The appliance is unusually
loud
The appliance is leaking
water
4
Probable cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not properly closed
Appliance is located near a heat source or air flow
to the condenser is being interrupted
Ambient temperature is too high
Appliance is overloaded
Loose nut/screw
The appliance has not been installed in a level or
stable position
The appliance is not properly levelled
The discharge outlet is blocked
The water container is damaged
L2G SAS 17, AVENUE DU 24 AOÛT 1944 - 69960 CORBAS
Check the unit is plugged in correctly
Call your agent or qualified technician
Call your agent or qualified technician
Call your agent or qualified technician
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler
Reduce the amount of containers in the appliance
Check and tighten all nuts and screws
Check installation position and change if
Adjust the screw feet to level the appliance
Call your agent or qualified technician
: +33(0)4 72 23 23 98 +33(0)4 72 23 23 99
www.L2Gfrance.fr
Action
Replace the fuse (UK Plug)
Check power supply
Defrost the appliance
position
necessary
Clear the discharge outlet