OPERATION INSTRUCTION :
Modify temperature setting value
1.
Under controller normal working status:
a) Press SET for more than 3 sec, setting light on, default display. Press
temperature setting value, press continuously to increase and decrease the setting value.
b) Press SET 3 sec or without operation in 15 sec to save values to be the normal status.
2.
Modify parameters setting value
a) Press SET and
b) When F0 code display, press
c) If need to change the parameter, enter to the corresponding code, press SET and the LED
displays the current setting value. Press
and decrease the setting value.
d) Press SET 3 sec or without operation in 15 sec to save values to be the normal status.
e) Power button : press
Menu :
Code
F0
F1
F2
Limit of lower temperature setting value
F3
Limit of high temperature setting value
F4
F5
F6
F7
F8
Exceeding Temp. highest limits alarm
CLEANING, CARE ET MAINTENANCE
ROUTINE MAINTENANCE
Disconnect from the power supply before cleaning.
• Clean the enclosure and interior of the cabinet as often as possible.
• Clean the unit with moist cloth. Never allow the switch, control panel, cable or plug to get wet.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• Use only mild soapy water.
• Clean the door seal with water only.
• Ensure that no cleaning water penetrates into the electrical components.
• Must not be cleaned by a water jet.
• Always wipe dry after cleaning with soft cloth.
• Take care when cleaning the rear of the cabinet.
• An agent or qualified technician must carry out repairs if required.
• If the cabinet is to be left inactive for long periods, unplug the cabinet after having turned the lamp
switch to off position, empty the refrigerating compartment and clean thoroughly.
3
at the same time for 3 sec, setting light on, entre to menu.
or
to change the code from F0 to F8.
3 sec to power off, press
Function
Temperature setting value
Return difference
Compressor delay protection time
Defrost cycle
Defrost time
Temperature calibration
Exceeding Temp. lowest limits alarm
L2G SAS 17, AVENUE DU 24 AOÛT 1944 - 69960 CORBAS
or
to modify the value. Press continuously to increase
to power on.
Parameter range
1-16
0-8
-50-setting value
setting value-99
0-36
0-99
-12-12
-50-highest limit
Lowest limit-99
: +33(0)4 72 23 23 98 +33(0)4 72 23 23 99
www.L2Gfrance.fr
or
to modify
Default
Unit
0
3
°C
3
Min
-20
°C
20
°C
6
Hrs
30
Min
0
°C
-50
°C
99
°C