MPPES
Wire the MPPES-...- according to one of the connection arrangements: Fig. 9 or Fig. 10
Fig. 9
Voltage variant
Pin
no.
1
1)
2
1)
3
4
5
6
7
1)
8
1) Internally connected
Tab. 2
Festo – MPPES – 1501e English
Voltage variant
Current variant
–
–
1)
Ground setpoint value
1)
Ground supply
Setpoint value
Setpoint value
DC 0 ... 10 V
4 ... 20 mA
–
Actual value -
Actual value -
output
output
DC 0 ... 10 V
4 ... 20 mA
DC 24 V supply voltage
1)
Ground actual value
max. 500 Ω
Fig. 10
Current variant
Cable colour when the socket
with cable type KMPPE-... is
used, according to accessories
WH
BN
GN
YE
GY
PK
RD
BU
White
Brown
Green
Yellow
Grey
Pink
Red
Blue
19