Always use an isothermal cover for optimal performance and to save energy.
IMPORTANT:
Performance cannot be guaranteed outside the operating ranges and must take account of the exterior
conditions and the conditions of use identified when selecting the model (location, annual heating period,
required temperature, daily duration of filtering, daily period when the pool is covered, number of
bathers, type of hydraulicity, etc.).
Non-contractual scheme, pool water input / output water on back side
Dim (mm)
A
104274
234
104275
313
104276
313
105417
313
105418
313
104279
424
LIST OF ITEMS SUPPLIED
1 heat pump + 2 x 50mm diameter fittings + condensate drain kit
-
1 digital remote control panel
-
1 manual
-
STEPS IN THE INSTALLATION PROCESS
Position
- The heat pump must be installed OUSTSIDE in a well ventilated place, far from any sources of
combustibles. In order to reduce noise levels :
- Do not direct ventilation towards neighboring
- Avoid corners and courtyards that increase the reflection of sound transmitted and received
(eg against a wall: + 3 dB (A) in a corner: + 6 dB (A), in a courtyard: + 9 dB (A))
- Install the CAP away from property lines and comply with the established rules private property
- Do not install under windows
Refer to national laws regarding the struggle against neighborhood noise
The water pipe between the pool and the heat pump must not exceed 10m.
Provide for the discharge by gravity of condensates under the machine.
For maintenance reasons, the pump must not be placed in an area where vegetation is present (leaves,
pine needles, etc.).
Ideally, the heat pump should be protected against outdoor phenomena (rain, snow, etc.) by a shelter.
NOTPACAQX - ind S – 0315
B
C
590
312
590
392
590
392
720
391
720
391
790
496
D
E
278
961
357
961
357
961
357
1092
357
1092
468
1161
13/41
C
A
D
F
G
280
77
310
77
310
77
600
77
600
77
620
77
H
658
658
658
958
958
958