3-Wire Cable from Power Supply
IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire.
A
B
C
D
E
A. 3-wire cable from power
supply
B. Red wire from power supply
C. White wire from cooktop cable
D. Green (or bare) ground wire
from cooktop cable
E. 3-wire cable from cooktop
1. Connect the 2 black wires together using the UL listed wire
connectors.
2. Connect the red wire from power supply to the white wire
from the cooktop cable using the UL listed wire connectors.
3. Connect the green or bare cooktop cable wires to the white
(neutral) wire in the junction box using the UL listed wire
connectors.
4. Install junction box cover.
6
F
G
H
I
J
F. Junction box
G. White wire from power supply
H. UL listed wire connector
I. Black wires
J. UL listed or CSA approved
conduit connector with wire
bushing
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all your tools.
3. Dispose of/recycle all packaging materials.
4. Use a mild solution of liquid household cleaner and warm
water to clean cooktop before use. Dry thoroughly with a soft
cloth. For more information, see the "Cooktop Care" section
of the Use and Care Guide.
5. Read the "Cooktop Use" section in the cooktop Use and
Care Guide.
6. Reconnect power.
NOTE: If the cooktop does not work after turning on the power,
check that a circuit breaker has not tripped or a household fuse
has not blown. See "Troubleshooting" section in the Use and
Care Guide for further information.
If You Need Assistance or Service:
Please reference the "Assistance or Service" section of the Use
and Care Guide or contact the dealer from whom you purchased
your cooktop.