longer period. When it is cold and there is a risk of frost, you must drain the pump,
otherwise it will suffer frost damage. Frost damage is not covered by the warranty!
If the pump will not be used for a significantly long period it should be cleaned and
stored in a dry, well ventilated place.
Fault indicator
Fault:
The group does not switch off automatically: Cause and solution 2, 5 or 7
The motor is running but not supplying water: Cause and solution 4 or 5
The pressure is insufficient: Cause and solution 4, 5 or 7
The group switches on and off continuously: Cause and solution 2 or 7
The group does not start up: Cause and solution 3, 6 or 8
Cause and solution:
1. Check the non-return valve in the suction hose
2. Leakage at a tap. Seal the leak.
3. The pump is blocked or dirty. Clean the pump or call the service department
4. Water is too deep. Check the discharge head.
5. Air is drawn in. Tightly seal all connections and connectors.
6. No power. Check the plugs and the ground fault.
7. Leakage in the drainage pipes. Seal the leak.
8. The water pressure is higher than the starting pressure of the pressure
switch; check if the initial settings are correct.
If malfunctions other than those mentioned above occur, or if the suggested solu-
tions do not solve the problem, please contact your customer service.
Removal
CE-declaration
See page 38.
In the EU this symbol indicates that this product may not be
disposed of as ordinary household waste. Old equipment contains
valuable materials, suitable for recycling. These materials should
be made suitable for reuse in order to prevent any adverse effects
to health and the environment caused by unregulated waste
collection. Therefore, please make sure that you bring old
equipment to a designated collection point. Alternatively, contact
the original supplier, who can make sure that as many of the
components as possible can be recycled