Use coolant accumulator
9.1
Display and control elements of devices with
TEC program control
No. in
fig. 2,
Explanation
page 3
1
Green LED: Indicates that the compressor is working.
2
Yellow LED: indicates that the external power supply is present (voltage is
higher than 13.5 V or 27.0 V).
The LED flashes if the external power supply is too low (voltage ≤ 10.7 V or
21.7 V. Version E: ≤ 10.7 V or 22.0 V).
3
Red LED: indicates that the accumulator is being discharged because
•
the discharge button has been pressed
Low voltage shutdown (voltage ≤ 10.7 V or 21.4 V. Version E: ≤ 10.7 V or
•
22.0 V).
4
Accumulator discharge button: interrupts compressor operation until
•
the stored cold energy is exhausted
•
The external supply voltage level is restored after low voltage.
5
Temperature selector: allows the temperature in the cooling area to be set
as required
Min. (left limit) = warmest setting
Max. (right limit) = coldest setting
6
Main switch: for switching the cooling device on and off.
Position 0 = OFF
Position – = ON