MASTER/SLAVE OPERATION
This function will allow you to link up to 16 units together and operate without a controller. In a Master-Slave set up one unit will
act as the controlling unit and the others will react to the controlling unit's programs. Any unit can act as a Master or as a Slave.
1. Using approved DMX data cables, daisy chain your units together via the XLR connector on the rear of the units. Remember
the Male XLR connector is the input and the Female XLR connector is the output. The first unit in the chain (master) will use the
female XLR connector only - The last unit in the chain will use the male XLR connector only. For longer cable runs we suggest a
terminator at the last fixture.
2. For the Master unit press the MENU button until "SLND" is displayed, and press ENTER. Set the unit to "MAST" and press
ENTER.
3. Next set the Master to your desired operating mode.
4. For the slave units press the MENU button until "SLND" is displayed, and Press ENTER. Set the slave units to either "SL 1"
or "SL 2". 5. The slave units will now follow the Master unit.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit's optics.
•
Make sure the area below the installation place is free from unwanted persons during servicing.
•
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation.
•
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected.
•
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
•
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
•
Clean with soft cloth using normal glass cleaning fluid.
•
Always dry the parts carefully.
•
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION: We strongly recommend internal cleaning to be carried out by qualified worker!
7