Error messages

In case of any faults, a fault message (1) and a fault code (2) appears on the display.
Low voltage detected on voltage bus.
Check the power supply connection.
1
2011-09-09 12:45
2
CODE: F0109
Measures for acknowledging fault messages:
Press "OK" on the display or activate the throttle control on the connected tool.
No further action is required if the fault message is deleted.
If the system freezes and an acknowledgment can not be made:
Turn the switch to the OFF position (O). Pull the plug out of the grounded socket, connect the power source (see
Starting and Stopping section) and restart the system.
If the fault persists, follow the instructions given in the troubleshooting guide or get in touch with an authorized dealer.
Please observe, the illustration shows an example.
The power unit software can be updated. Contact your service agent for further information.

Troubleshooting schedule

Fault Code Error messages
F0101
Overcurrent detected
F0103
Hardware fault detected
F0104
Fault detected on power bus
Overvoltage detected on power
F0105
bus. Check the voltage supply.
The temperature in the IGBT
F0106
module is too high
F0107
Emergency stop depressed
The motor temperature sensor
FXX08*
is too high.
Undervoltage detected on
F0109
power bus. Check the voltage
supply.
Clock stopped, please set it
F0111
correc
F0112
Undervoltage detected
F0113
Overvoltage detected
Fault detected in tool
FXX14*
temperature sensor
F0118
Hardware fault detected
The temperature in the PP is
F0119
too high
* XX different numbers depending on the tool that is connected to the power unit.
16 – English
MAINTENANCE
OK
OK
Cause
Active tool current too high
Hardware fault
Tool voltage error
Brakes applied too hard
Power pack overheated
The emergency stop is
pressed in.
Tool motor temperature is
too high
Internal power pack failure
Clock stopped
Input voltage too low
Input voltage too high
Interruption or short circuit
in the temperature sensor.
Hardware fault
Power pack overheated
Steps
Contact your service workshop if the
problem remains.
Contact your service workshop if the
problem remains.
Check the power supply
Contact your service workshop if the
problem remains.
Check the fan and filter and allow the
system to cool down.
Reset the emergency stop
Increase the flow of water coolant. Refer
to Technical Data in the instruction
manual for the connected t
Check input power or contact service
Contact your service agent for a battery
change.
Check minimum input power in manual
Check maximum input power in manual
Contact your service agent.
Contact your service workshop if the
problem remains.
Check the fan and filter and allow the
system to cool down.