ENGLISH
Terminal7 - 230 Vac motor M2 power supply phase (closure)
Terminal8 - 230 Vac motor M2 power supply phase (opening)
Note: connect the capacitor of the motor M2 between terminals 8 and 7
Terminal board J6
Terminal1 – Electric lock 12 Vac power supply
Terminal2 – Electric lock 12 Vac and 24 Vac power supply (common)
Terminal3 – 24Vac power supply for photo-cells or other devices
Terminal4 – M1 Opening limit switch normally closed electric contact
Terminal5 – M1 Closing limit switch normally closed electric contact
Terminal6 – M2 Opening limit switch normally closed electric contact
Terminal7 – M2 Closing limit switch normally closed electric contact
Terminal8 – Common terminal for all electric contacts of limit switches
Terminal9 – Pedestrian start push-button's normally open electric contact
Terminal10 – Photo-cell normally closed electric contact
Terminal11 – Emergency push-button's normally closed electric contact (stop)
Terminal12 – Start push-button's normally open electric contact
Terminal13 – Common terminal for all electric contacts of commands or security devices
Important: The normally closed inputs not in use must be fitted with jumpers
Terminal14 – 2nd radio-channel's normally open electric contact (output)
Terminal15 – 2nd radio-channel's normally open electric contact (output)
Terminal board J6
Terminal1 – Aerial cable connection (shield) for radio receiver card
Terminal2 – Aerial cable connection (signal) for radio receiver card
Connector J3
Terminal1 – 230 Vac mains power supply neutral
Terminal2 – 230 Vac motors M1 and M2 Power supply common
Terminal3 – 230 Vac motors M1 and M2 Power supply common
Terminal4 – 230 Vac motors M1 and M2 Power supply common
Important: If the power regulator card is not connected the J3 connector's terminals 1 and 2 must be bridged with 4 mm insulated faston
terminal
26