TCS-NET GSM Phone Control Interface
REQUIREMENT
• Output voltage: 7-19 V ± 5 %
• Output current: Min. 0.1 A
• Shall conform to IEC safety standards (including EN60950-1 or IEC 60950-1, etc), and shall have been certified
as required for EMI standards (EN550022 and EN61000-3) and EMS standards (including EN50024,
(EN61204-3), and EN61000-4).
• Shall meet environmental conditions and required lifetime.
• DC Plug 2.1mmØ (inner diameter)
5.5mmØ (outer diameter)
10mm
Recommended product is
Model name: UI312-1508 produced by UNIFIVE TECHNOLOGY CO., LTD
Homepage addresses of UNIFIVE TECHNOLOGY CO., LTD are
http://www.unifive-us.com/, http://www.unifive.com.tw/, http://www.unifive.co.kr/, http://www.unifive.com/ or http:/
www.unifive-c.com/.
Parts Supplied with the Product and Required Materials
Part name
GSM Phone Control
Interface TCB-IFGSM1E
GSM modem
Power supply
RS-232C cable
Indoor unit cable
Insulating tube for cable
protection
Screw
Foot
Cable clamp
Installation Manual
Owner's Manual
Parts Required for Tests
GSM modem simulator
software (CD-ROM)
PC for tests
RS-232C cable for tests
Write down the GSM modem telephone number, PIN, and PUK number.
GSM modem telephone number:
PIN:
PUK number:
7-EN
(length)
Description / Specification
This product
Provided with an RS-232C connector and the SMS-related AT
command function.
Conforming to ETSI GSM 07.05, GSM 07.07, GSM 03.40, and
GSM 03.38 standards.
Not required when CN61 is used.
Used for connection to between GSM modem and TCB-IFGSM1E.
A straight cable with male-female connectors (max.15 m)
Use a commercially available 6-pin cable for connection to CN61.
(Model name: TCB-KBCN61HAE)
Use a 1.9 m 4-pin cable for connection to HA terminal.
Use this tube (Thickness: at least 1 mm) to protect the indoor unit
cable if the user may touch the cable.
For 4 feet to be attached to the wall (M3 x 16 tapping screw)
4 feet (including screws MT-34K) to be attached to the TCB-
IFGSM1E.
For clamping indoor unit cable.
Used by installation staff
Used by the user
Used for checking air conditioner communication and RS-232C
communication.
Equipped with RS-232C communication function. Used for the
GSM modem simulator software.
A cross cable with female-female connectors used for connection
to a PC
– 8 –
Installation Manual
Quantity Procurement
1
Supplied
1
Procured locally
(including power
supply)
1
Procured locally
1
Procured locally
1
Procured locally
Ask your dealer.
1
Supplied
1
Procured locally
4
Supplied
4
Supplied
1
Supplied
1
Supplied
1
Supplied
1
Supplied
1
Procured locally
1
Procured locally