1. Overview of the battery
1.1. Symbols
The voltage of the battery is higher than the safety voltage, a direct contact can cause an electric shock
Faites attention à vos actions et soyez conscient des dangers.
Read the user's manual before use.
The battery must not be mixed with household or industrial waste, it must be taken care of and recycled by
professionals.
EN
Once the life of the battery has been reached, the battery can be recycled by a professional recycling
organization and should not be thrown away.
FR
FR
This battery meets the requirements of the European directive.
1.2. Connections
1.2.1. Front panel connectors
Name
1
Switch
2
Ground
connection
3
Positive pole
4
Negative pole
5
ADD
6
SW
(standby
switch)
7
SOC
8
ALM
9
RUN
10
CAN/485
11
DRYCONTACT
IM4850DA_guide_installation_v.A.4
1
2
3
5
6
7 8 9
OFF / ON
Positive battery output line or parallel positive line
Negative battery output line or parallel negative line
DIP switch
When the "OFF/ON" switch button is set to ON, press and hold the button for 3 seconds to turn
the battery on or off.
The number of green lights on indicates the remaining battery capacity.
Flashing red light: An alarm has been triggered on the battery.
Red light on and steady: The battery is in error.
Indicates battery operating status.
Flashing green light: Battery is in standby mode or charging
Green light on and flashing: The battery is charging or in standby mode see (§1.2.4).
Green light on and fixed: The battery is being discharged.
Cascade communication port, supporting CAN/RS485 communication (CAN communication by
default)
/
10 11
4
Description
17/ 24